国产精品无码素人福利_亚洲午夜在线x88v_欧洲亚洲免费视频三区_无码人妻久久一区二区三区

Enquiry Hotline

15864583687

    Enquiry number: +8615864583687 +8618663615891

PRODUCT
24-hour counselling hotline

+8615864583687 +8618663615891

  • FGM gas box pulse bag filter (click to enter)
FGM gas box pulse bag filter (click to enter)

Category:Bag filter

  • 售后QQ: 點(diǎn)擊這里給我發(fā)消息
  • 售后QQ: 點(diǎn)擊這里給我發(fā)消息
Hotline:+8615864583687
Details

The FGM air box pulse bag filter (plenum pulse) is a dust collector introduced from the American company Fuiler. This type of dust collector has advantages over other types of dust collectors, such as insufficient kinetic energy intensity during chamber blowback and simultaneous filtering and cleaning of dust with pulse blowing. Therefore, it increases the adaptability of bag dust collectors, improves dust collection efficiency, and prolongs the service life of filter bags. On the entire cement production line, not only can it be used as a dust collection equipment for crushers, dryers, coal mills, grate coolers, and cement mills, but its high concentration and rate type can also be directly used as a raw material vertical mill outlet concentration (500g/Nm) gas.

The 0-Spea powder selection machine is used for dust collection of gas with an outlet concentration of 1000g/Nm, and the dust concentration of the collected gas is less than 100g/NM. The filter bag adopts polyester needle punched felt filter material, and the average service life can reach more than two years. At present, the equipment has been widely used, not only quickly selected in cement plants, but also promoted and used in industries such as steel and carbon black.

The gas box pulse dust collector is divided into several box areas, with 32, 64, 96, 128 bags per box. And there is a lift valve driven by a cylinder on each outlet pipe of the box. When the resistance of the dust collector reaches the pre selected value (usually 1500pa), the dust cleaning controller sends a signal. The lift valve of each compartment begins to close to cut off the filtered airflow. Then the solenoid valve of this box is opened (one per box, pressure not less than 0.5MPa), and compressed air flows into the cleaned filter bag to remove the dust. After this action is completed (approximately 10-15 seconds), the lift valve on the outlet pipe will reopen, allowing the box to resume filtering work and follow the above requirements one by one until all dust is cleared.

  The pneumatic pulse bag dust collector adopts a separate chamber for dust cleaning. During dust cleaning, it is isolated and rotated box by box to avoid the secondary flying problem of the jet pulse bag dust collector. At the same time, the compressed air cleaning effect is ensured. The entire box design utilizes a compartment structure, and the ash hopper can be extended to the inlet main pipe. The incoming dusty flue gas directly enters the enlarged ash hopper to achieve pre dust collection effect, and can remove horizontal straight pipes that are prone to blockage. So, the segmented pulse bag filter can not only handle dust containing gases of general concentration, but also handle dust containing gases with a concentration of up to 1000g/Nm.

This dust collector uses a full box large pulse valve for back blowing and jet cleaning. When removing the bag, open the top cover and directly remove the filter bag, making maintenance simple and versatile.

  & nbsp; & nbsp; Technical parameters

FGM32-3

FGM32-4

FGM32-5

FGM32-6

FGM64-4

FGM64-5

FGM64-6

FGM64-7

FGM64-8

Processing air volume(mthree/h

five thousand and seven hundred

seven thousand and six hundred

nine thousand and six hundred

eleven thousand five hundred and twenty

fifteen thousand three hundred and sixty

nineteen thousand and two hundred

twenty-three thousand and forty

twenty-six thousand and eight hundred

thirty thousand and seven hundred

Filter wind speed(m/min

1.0-2.0Select different filtered wind speeds based on different dust emission points, as shown in the tableone

Total filtration area(mtwo

ninety-three

one hundred and twenty-four

one hundred and fifty-five

one hundred and eighty-six

two hundred and forty-eight

three hundred and ten

three hundred and seventy-two

four hundred and thirty-four

four hundred and ninety-six

Filtration area(mtwo

sixty-two

ninety-three

one hundred and twenty-four

one hundred and fifty-five

one hundred and eighty-six

two hundred and forty-eight

three hundred and ten

two hundred and seventy-two

four hundred and thirty-four

Number of dust collector rooms (pcs)

three

four

five

six

four

five

six

seven

eight

Total number of filter bags (pieces)

ninety-six

one hundred and twenty-eight

one hundred and sixty

one hundred and ninety-two

two hundred and fifty-six

three hundred and twenty

three hundred and eighty-four

four hundred and forty-eight

five hundred and twelve

Dust collector resistance(Pa

1440-1740

Imported gas dust concentration(g/m3

 200 

 200 

Imported gas dust concentration(g/mthree

zero point one

Dust collector gas bears negative pressure(Pa

six thousand

Compressed air for dust cleaning

Pressure(Pa

5-7)×tenfive

Gas consumption(m3/min

zero point two

zero point two one

zero point three

zero point three five

zero point five

zero point five

zero point eight

one

one

Pulse valve (with solenoid valve)

Quantity (piece)

three

four

five

six

four

five

six

seven

eight

Specifications(mm

twon

Lift valve (with cylinder)

Quantity (piece)

three

four

five

six

four

five

six

seven

eight

Specifications(mm

Increase the diameter of the valve plate?460, cylinder diameter?63

Increase the diameter of the valve plate?500, cylinder diameter?80

Rigid impeller feeder

Discharge portthree hundred×300mm,height450mm,speed30.31r/min,Power of deceleration motor1.1kwProduction volume24mthree/h

screw

Specifications

diameter?300Production volume30mthree/h(Filling rate Zeta=0.7

Conveyor

Gear motor

model:XWD2.2-5-1/43,power2.2kw

Air conveying chute

If the dust concentration in the imported gas is greater than700g/mthreeThe standard and ash discharge device should use larger sized screw conveyors or air chutes

Dust cleaning program controller

The transmission voltage is220v,The controller is supplied by the manufacturer, please refer to the controller manual for detailed information

Dust cleaning program controller

Diameter and length Φone hundred and thirty×2450mm,Weight of polyester needle punched felt500g/m2Usage temperatureeighty

Insulation layer area

twenty-six point five

twenty-four

forty-one

forty-eight point five

seventy

ninety-four

one hundred and eighteen

one hundred and forty-two

one hundred and sixty-two

Total weight of equipment (approximate value, excluding insulation layer)(kg

two thousand and four hundred

three thousand and four hundred

four thousand and four hundred

five thousand and four hundred

six thousand and nine hundred

eight thousand and three hundred

nine thousand and seven hundred

eleven thousand and one hundred

twelve thousand and five hundred

External dimensions

two thousand and fifteen×one thousand nine hundred and eighty
four thousand seven hundred and fifty

two thousand and fifteen×two thousand six hundred and forty
four thousand seven hundred and fifty

two thousand and fifteen×three thousand and three hundred
four thousand nine hundred and fifty

two thousand and fifteen×three thousand nine hundred and sixty
five thousand one hundred and twenty

two thousand one hundred and fifteen×five thousand one hundred and twenty
h:4750

two thousand one hundred and fifteen×six thousand and four hundred
h:4950

two thousand one hundred and fifteen×seven thousand six hundred and eighty
h:5210

two thousand one hundred and fifteen×eight thousand nine hundred and sixty
h:5470

ten thousand two hundred and forty
h:5770


twoThe gas consumption in the table refers to the situation of centralized gas supply in the factory. If a separate air compressor is set up, the gas consumption in the table is multiplied byone point threeCoefficient.

threeThe gross filtration wind speed for processing air volume in the table is1.2m/minCalculated by time, the dust concentration at the user's dust source point is only less than30g/mthree(mark)In the case where the filtered air velocity is also unknown, the selection should be made directly according to the processing air volume indicated in the table.

The data of the equipment can be improved at any time according to the actual situation on site, and the interpretation right belongs to our company.

分享到: